How the rebar weight formula works
Steel has a density of about 7,850 kg/m³. The weight of one metre of a round bar is its cross-section area × density, which simplifies to the well-known site formula:
Weight (kg/m) = d² ÷ 162.2 ≈ 0.00617 × d² (d in mm)So a 16 mm bar weighs 16² ÷ 162.2 = 1.578 kg/m, and ten 12 m lengths weigh 1.578 × 12 × 10 = 189.4 kg.
For US bars the calculator uses the nominal weights from ASTM A615 / A706 (for example #4 = 0.668 lb/ft, #5 = 1.043 lb/ft). The bar number is the diameter in eighths of an inch, so #5 is 5/8 in.
Rebar weight chart
| Metric bar | kg/m | US bar | lb/ft | kg/m |
|---|---|---|---|---|
| 8 mm | 0.395 | #3 | 0.376 | 0.560 |
| 10 mm | 0.617 | #4 | 0.668 | 0.994 |
| 12 mm | 0.888 | #5 | 1.043 | 1.552 |
| 16 mm | 1.578 | #6 | 1.502 | 2.235 |
| 20 mm | 2.466 | #7 | 2.044 | 3.042 |
| 25 mm | 3.853 | #8 | 2.670 | 3.973 |
| 32 mm | 6.313 | #9 | 3.400 | 5.060 |
| 40 mm | 9.864 | #10 | 4.303 | 6.404 |
How to use this calculator
- Pick Metric or Imperial at the top.
- Select the bar diameter or US bar size.
- Enter the length of one bar and the number of bars.
- Optionally add a lap / waste allowance (5–10% is typical for laps and offcuts).
Frequently asked questions
What is the formula for rebar weight per metre?
Weight in kg/m = d² ÷ 162.2 (or 0.00617 × d²), where d is the bar diameter in millimetres. It comes from the density of steel, 7,850 kg/m³.
How much does a #4 rebar weigh?
A #4 bar (1/2 inch) weighs 0.668 lb per foot, so a standard 20 ft length weighs about 13.4 lb (6.06 kg).
How many 12 mm bars make one tonne?
One 12 m length of 12 mm bar weighs about 10.66 kg, so roughly 94 bars make one tonne.
Why is 162 used in the rebar formula?
162.2 is 1 ÷ (π/4 × 7,850 ÷ 1,000,000). It converts d² in mm² into kg per metre using the density of steel.
Should I add waste to rebar quantities?
Yes. Add 3–5% for offcuts and more if your design uses many laps. For exact quantities, prepare a bar bending schedule.
Last updated 2026-11-26. These results are estimates for planning and ordering. Structural designs must be checked by a qualified engineer.